The validation study of a new fluorescence-target tracer for sentinel lymph node biopsy
)。透析纯化后的新型增强靶向示踪剂中未检测到细菌和热原。实验动物局部注射,观察2周后,局部及全身无红肿也无皮疹,无死亡。Rit与Cy754偶联的最佳的物质的量比为1∶80。Cy754-Rit能够准确地定位前哨淋巴结,其定位特性与核素相似,但发射荧光穿透力优于ICG-Rit(14.3 mm vs 13.2 mm)。结论:Cy754-Rit的制备工艺简便、高效、无放射性,其荧光强度较传统荧光靶向示踪剂明显增强。经动物模型局部注射能够准确地定位到前哨淋巴结,显像清晰稳定,穿透力好,但仍需临床试验进行相关验证。
Abstract
Background and purpose: Tracer is the key to sentinel lymph node biopsy
but the traditional fluorescence tracer could not target at sentinel lymph node with weak intensity. A new near-infrared fluorescence tracer polymethylene cyani
ne dye Cy754 with stronger permeability and intensity was synthetized and combined with rituximab (Rit) to produce a new near-infrared fluorescence-target tracer Cy754-Rit. Methods: The new near-infrared fluorescence tracer Cy754 was synthetized by chemical method
and the basic parameters including molecular weight
absorption and emission spectra were tested. The molecule of Cy754 was combined directly with Rit to produce Cy754-Rit. The Cy754-Rit was analyzed for labeled rate
molecular integrity
and molecular immune activity. The fluorescence intensity of Cy754-Rit was compared with indocyanine green (ICG)-Rit by using near-infrared fluorescence detector. The safety limitation was tested. The localization ability of Cy754-Rit was tested in animal model of sentinel lymph node and compared with Cy754
ICG-Rit and radiotracer. Results: The molecular weight of Cy754 was 818
and the absorption and emission spectra were 740 nm and 760 nm. The Cy754-Rit was intact and kept the immune activity of Rit. The Cy754 labeled rate of Rit was 100%. The fluorescence intensity of Cy754-Rit was stronger than that of ICG-Rit (3.08×10
10
vs 6.56×10
8
). The Cy754-Rit was bacteria- and pyrogen-free
and was safe to body with location injection. The best molarity ratio of Cy754-Rit was 80∶1. The Cy754-Rit could identify the location of sentinel lymph node which was accorded with the radiotracer and had a stronger permeability than ICG-Rit (14.3 mm vs 13.2 mm). Conclusion: The method of producing Cy754-Rit is simple
effective and non-radioactive. The fluorescence intensity of Cy754-Rit is stronger than that of traditional tracer. The Cy754-Rit could identify the location of sentinel lymph node in the animal model of sentinel lymph node but should be validated by clinical trial before its use in clinical practice.